Skip to main content
IIDM Logo
750-889

Description

This controller can accommodate up to two KNX logic devices at the same time. 1. In conjunction with the WAGO I/O System, the KNX IP Controller is used as a user-programmable application controller within KNX IP networks. The controller supports all digital, analog and specialty modules found within the 750/753 Series. The IEC 61131-3 programmable controller is capable of 10/100 Mbit/s data rates. KNX objects of any type (EIS/DPT) can be created using the programming tool. Libraries including pre-made function blocks are readily available on the WAGO Website for programming. The controller supports a maximum of 253 communication objects, as well as 254 group addresses and associations. 2. Combined with the KNX/EIB/TP1 Module, the 750‐889 KNX IP Controller operates as a router on an IP backbone (ETHERNET). No IEC application is required for router functionality. Both devices are commissioned and configured via ETS software using the WAGO product database. The software includes a plug‐in that automatically installs and opens for configuration. The KNX IP Controller features an integrated 2‐port 10/100 Mbit/s switch, allowing a line structure to be easily created without additional network components. The maximum number of controllers that can be wired in series is 20. An internal server is available for Web-based applications. The controller provides 1024 KB program memory, 1024 KB data memory and 32 KB retain memory. It is capable of multitasking, has a battery-backed, real-time clock and is based on a 32-bit CPU. The controller offers many different application protocols for control tasks (MODBUS, KNXnet/IP) or for system management and diagnostics (HTTP, BootP, DHCP, DNS, AutoIP, SNTP, FTP, SNMP and SMTP). The number of KNX/EIB/TP1 Modules (750‐646) supported by the KNX IP Controller does not depend on the application.

Notes

Note

The WAGO ETS3/4 plug-in is a component of the WAGO-ETS3 product databank and can be downloaded for free at www.wago.com.

Technical data

Communication

KNX IP

Modbus (TCP, UDP)

ETHERNET

ETHERNET protocols

HTTP

BootP

DHCP

DNS

AutoIP

SNTP

FTP

SNMP V3

SMTP

Visualization

Web-Visu

CPU

32 bits

Programming languages per IEC 61131-3

Instruction List (IL)

Ladder Diagram (LD)

Function Block Diagram (FBD), Continuous Function Chart (CFC)

Structured Text (ST)

Sequential Function Chart (SFC)

Programming environment

WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)

Configuration options

WAGO-I/O-CHECK

Web-Based Management

Device specification

KNX/TP1 bus specification: 1.0

Network length (max.)

≤ 2000 m; max. 20 controllers in series

Baud rate (communication/fieldbus 1)

10/100 Mbit/s

Baud rate

10/100 Mbit/s

Bus segment length (max.)

100 m

Transmission medium (communication/fieldbus)

S-UTP; 100 Ω; Cat. 5

Program memory

1024 KB

Data memory

1024 KB

Non-volatile software memory

32

Memory for fieldbus input variables (max.)

512

Memory for fieldbus output variables (max.)

512

Type of memory card

SD card

Memory card slot

Push-push mechanism; Cover lid (sealable)

Number of modules per node (max.)

250

Number of modules without a bus extension (max.)

64

Input and output process image (fieldbus) max.

1020 Worte/1020 Worte

Device-specific

Number of group addresses: 254; Number of communication objects: 253

Indicators

LED (LINK/ACT) green: Network connection via ports 1 … 2; LED (MS/PRG IP, NS/PRG RT) red/green: IP device programming mode, router; LED (I/O, USR) red/green/orange: Local data bus status, status programmable by user; LED (A, B) green: System power supply status, field supply

Supply voltage (system)

24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)

Input current (typ.) at nominal load (24 V)

500

Power supply efficiency (typ.) at nominal load (24 V)

90

Current consumption (5 V system supply)

450

Total current (system supply)

1,700

Supply voltage (field)

24 VDC (-25 … +30 %); via power jumper contacts

Current carrying capacity (power jumper contacts)

10

Number of outgoing power jumper contacts

3

Isolation

500 V system/field

KNX certified

IP Controller: 61/8316/08; IP Router: 61/8317/08

Connection data

Connection technology: communication/fieldbus

KNX IP: 2 x RJ-45; Modbus TCP/UDP: 2 x RJ-45

Connection technology: system supply

2 x CAGE CLAMP®

Connection technology: field supply

6 x CAGE CLAMP®

Connection type 1

System/field supply

Solid conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Fine-stranded conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Connection technology: device configuration

1 x Male connector; 4-pole

Physical data

Width

61.5 mm / 2.421 inches

Height

100 mm / 3.937 inches

Depth

71.9 mm / 2.831 inches

Depth from upper-edge of DIN-rail

64.7 mm / 2.547 inches

Mechanical data

Weight

192

Color

gray

Housing material

Polycarbonate; polyamide 6.6

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

0 … +55 °C

Surrounding air temperature (storage)

-25 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)

Relative humidity (without condensation)

95

Mounting position

any

Mounting type

DIN-35 rail

Vibration resistance

4g per IEC 60068-2-6

Shock resistance

15g per IEC 60068-2-27

EMC immunity to interference

per EN 61000-6-2

EMC emission of interference

per EN 61000-6-3

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Fire load

2.802

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Specifications

Connection data

Connectable Conductor MaterialsCopper
Connection Technology: Communication/FieldbusKNX IP: 2 x RJ-45; Modbus TCP/UDP: 2 x RJ-45
Connection Technology: Device Configuration1 x Male connector; 4-pole
Connection Technology: Field Supply6 x CAGE CLAMP®
Connection Technology: System Supply2 x CAGE CLAMP®
Connection Type 1System/field supply
Fine-Stranded Conductor0.08 … 2.5 mm² / 28 … 14 AWG
Solid Conductor0.08 … 2.5 mm² / 28 … 14 AWG
Strip Length8 … 9 mm / 0.31 … 0.35 inches

Environmental requirements

Ambient Temperature (Operation)0 … +55 °C °C
EMC Emission Of Interferenceper EN 61000-6-3
EMC Immunity To Interferenceper EN 61000-6-2
Exposure To PollutantsPer IEC 60068-2-42 and IEC 60068-2-43
Fire Load2.802
Mounting Positionany
Mounting TypeDIN-35 rail
Operating Altitudewithout temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
Permissible Pollutant Concentration H2S At A Relative Humidity < 75%10
Permissible Pollutant Concentration SO 2 At A Relative Humidity < 75%25
Pollution Degree (5)2 per IEC 61131-2
Protection TypeIP20
Relative Humidity (Without Condensation)95
Shock Resistance15g per IEC 60068-2-27
Surrounding Air Temperature (Storage)-25 … +85 °C
Vibration Resistance4g per IEC 60068-2-6

Mechanical data

Colorgray
Conformity MarkingCE
Housing MaterialPolycarbonate; polyamide 6.6
Weight192

Notes

NoteThe WAGO ETS3/4 plug-in is a component of the WAGO-ETS3 product databank and can be downloaded for free at www.wago.com.

Physical data

Depth71.9 mm / 2.831 inches mm
Depth From Upper-Edge Of DIN-Rail64.7 mm / 2.547 inches
Height100 mm / 3.937 inches mm
Width61.5 mm / 2.421 inches mm

Technical data

Baud Rate10/100 Mbit/s
Baud Rate (Communication/Fieldbus 1)10/100 Mbit/s
Bus Segment Length (Max.)100 m
CommunicationKNX IP | Modbus (TCP, UDP) | ETHERNET
Configuration OptionsWAGO-I/O-CHECK | Web-Based Management
CPU32 bits
Current Carrying Capacity (Power Jumper Contacts)10
Current Consumption (5 V System Supply)450
Data Memory1024 KB
Device-SpecificNumber of group addresses: 254; Number of communication objects: 253
Device SpecificationKNX/TP1 bus specification: 1.0
IndicatorsLED (LINK/ACT) green: Network connection via ports 1 … 2; LED (MS/PRG IP, NS/PRG RT) red/green: IP device programming mode, router; LED (I/O, USR) red/green/orange: Local data bus status, status programmable by user; LED (A, B) green: System power supply status, field supply
Input And Output Process Image (Fieldbus) Max.1020 Worte/1020 Worte
Input Current (Typ.) At Nominal Load (24 V)500
Isolation500 V system/field
KNX CertifiedIP Controller: 61/8316/08; IP Router: 61/8317/08
Memory Card SlotPush-push mechanism; Cover lid (sealable)
Memory For Fieldbus Input Variables (Max.)512
Memory For Fieldbus Output Variables (Max.)512
Network Length (Max.)≤ 2000 m; max. 20 controllers in series
Non-Volatile Software Memory32
Number Of Modules Per Node (Max.)250
Number Of Modules Without A Bus Extension (Max.)64
Number Of Outgoing Power Jumper Contacts3
Power Supply Efficiency (Typ.) At Nominal Load (24 V)90
Program Memory1024 KB
Programming EnvironmentWAGO-I/O-PRO V2.3 (based on CODESYS V2.3)
Programming Languages Per IEC 61131-3Instruction List (IL) | Ladder Diagram (LD) | Function Block Diagram (FBD), Continuous Function Chart (CFC) | Structured Text (ST) | Sequential Function Chart (SFC)
Supply Voltage (Field)24 VDC (-25 … +30 %); via power jumper contacts
Supply Voltage (System)24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)
Total Current (System Supply)1,700
Transmission Medium (Communication/Fieldbus)S-UTP; 100 Ω; Cat. 5
Type Of Memory CardSD card
VisualizationWeb-Visu

Similar products

More from Wago