Skip to main content
IIDM Logo
750-306

Description

This fieldbus coupler connects the WAGO I/O System as a slave to the DeviceNet fieldbus. The fieldbus coupler detects all connected I/O modules and creates a local process image. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit. The process image can be transferred via the DeviceNet fieldbus to the memory of the control system. The local process image is divided into two data zones containing the data received and the data to be sent. The process data can be sent via the DeviceNetTM to a control system for further processing. The process output data is sent via DeviceNetTM. The data of the analog modules is stored in the process image that is created automatically according to the order in which the modules are connected to the coupler. The bits of the digital modules are sent byte by byte and added to the analog data. If the amount of digital I/O information exceeds eight bits, the coupler automatically starts with a new byte.

Notes

Note

Note: Configuration files required (EDS)!

Technical data

Communication

DeviceNet

Number of fieldbus nodes on master (max.)

64

Number of I/O points

6,000

Baud rate

500 kBd (125 kBd, 250 kBd, 500 kBd)

Bus segment length (max.)

500 m

Transmission medium

Shielded Cu cable; Remote bus cable: 2 x 0.82 mm² + 2 x 1.7 mm²; Drop cable: 2 x 0.2 mm² + 2 x 0.32 mm²

Number of modules per node (max.)

64

DeviceNet features

Polled I/O message connection

Strobed I/O message connection

Change of state

Cyclic message connection

Group 2 only Slave

Input and output process image (fieldbus) max.

512 bytes/512 bytes

Supply voltage (system)

24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)

Current consumption (5 V system supply)

350

Total current (system supply)

1,650

Supply voltage (field)

24 VDC (-25 … +30 %); via power jumper contacts

Input current via DeviceNet interface at 11 V

120

Input current (typ.) at nominal load (24 V)

500

Power supply efficiency (typ.) at nominal load (24 V)

87

Isolation

500 V system/field

Number of outgoing power jumper contacts

3

Current carrying capacity (power jumper contacts)

10

Certification

ODVA

Connection data

Connection technology: communication/fieldbus

DeviceNet: 1 x Male connector; 5-pole

Connection technology: field supply

6 x CAGE CLAMP®

Connection technology: system supply

2 x CAGE CLAMP®

Connection technology: device configuration

1 x Male connector; 4-pole

Connection type 1

System/field supply

Solid conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Fine-stranded conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

50.5 mm / 1.988 inches

Height

100 mm / 3.937 inches

Depth

71.1 mm / 2.799 inches

Depth from upper-edge of DIN-rail

63.9 mm / 2.516 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

light gray

Housing material

Polycarbonate; polyamide 6.6

Fire load

3.302

Weight

200

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

0 … +55 °C

Surrounding air temperature (storage)

-25 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

0 … 2000 m / 0 … 6562 ft

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Vibration resistance

4g per IEC 60068-2-6

Shock resistance

15g per IEC 60068-2-27

EMC immunity to interference

per EN 61000-6-2, marine applications

EMC emission of interference

per EN 61000-6-4, marine applications

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Specifications

Connection data

Connectable Conductor MaterialsCopper
Connection Technology: Communication/FieldbusDeviceNet: 1 x Male connector; 5-pole
Connection Technology: Device Configuration1 x Male connector; 4-pole
Connection Technology: Field Supply6 x CAGE CLAMP®
Connection Technology: System Supply2 x CAGE CLAMP®
Connection Type 1System/field supply
Fine-Stranded Conductor0.08 … 2.5 mm² / 28 … 14 AWG
Solid Conductor0.08 … 2.5 mm² / 28 … 14 AWG
Strip Length8 … 9 mm / 0.31 … 0.35 inches

Environmental requirements

Ambient Temperature (Operation)0 … +55 °C °C
EMC Emission Of Interferenceper EN 61000-6-4, marine applications
EMC Immunity To Interferenceper EN 61000-6-2, marine applications
Exposure To PollutantsPer IEC 60068-2-42 and IEC 60068-2-43
Mounting Positionhorizontal (standing/lying); vertical
Operating Altitude0 … 2000 m / 0 … 6562 ft
Permissible Pollutant Concentration H2S At A Relative Humidity < 75%10
Permissible Pollutant Concentration SO 2 At A Relative Humidity < 75%25
Pollution Degree (5)2 per IEC 61131-2
Protection TypeIP20
Relative Humidity (Without Condensation)95
Shock Resistance15g per IEC 60068-2-27
Surrounding Air Temperature (Storage)-25 … +85 °C
Vibration Resistance4g per IEC 60068-2-6

Material data

Colorlight gray
Conformity MarkingCE
Fire Load3.302
Housing MaterialPolycarbonate; polyamide 6.6
Weight200

Mechanical data

Mounting TypeDIN-35 rail

Notes

NoteNote: Configuration files required (EDS)!

Physical data

Depth71.1 mm / 2.799 inches mm
Depth From Upper-Edge Of DIN-Rail63.9 mm / 2.516 inches
Height100 mm / 3.937 inches mm
Width50.5 mm / 1.988 inches mm

Technical data

Baud Rate500 kBd (125 kBd, 250 kBd, 500 kBd)
Bus Segment Length (Max.)500 m
CertificationODVA
CommunicationDeviceNet
Current Carrying Capacity (Power Jumper Contacts)10
Current Consumption (5 V System Supply)350
DeviceNet FeaturesPolled I/O message connection | Strobed I/O message connection | Change of state | Cyclic message connection | Group 2 only Slave
Input And Output Process Image (Fieldbus) Max.512 bytes/512 bytes
Input Current (Typ.) At Nominal Load (24 V)500
Input Current Via DeviceNet Interface At 11 V120
Isolation500 V system/field
Number Of Fieldbus Nodes On Master (Max.)64
Number Of I/O Points6,000
Number Of Modules Per Node (Max.)64
Number Of Outgoing Power Jumper Contacts3
Power Supply Efficiency (Typ.) At Nominal Load (24 V)87
Supply Voltage (Field)24 VDC (-25 … +30 %); via power jumper contacts
Supply Voltage (System)24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)
Total Current (System Supply)1,650
Transmission MediumShielded Cu cable; Remote bus cable: 2 x 0.82 mm² + 2 x 1.7 mm²; Drop cable: 2 x 0.2 mm² + 2 x 0.32 mm²