Ground fault circuit interrupter (GFCI) breakers provide protection of receptacles located in the outdoors, in bathrooms, garages and spa areas. This applies to not only to new construction, but also to existing homes. When an electrical outlet is replaced in a location that requires ground-fault protection, the new outlet must be GFCI approved according to the NEC. All Q Line circuit breakers are one inch wide per pole, compact devices that feature: Quick-make / Quick-break mechanisms, common trip bars, and easy-to-spot trip indications to ensure safety and reliability as well as meets 2020 NEC standards. The THQL1130GFT breaker features ground fault interrupting technology, 1 pole, an ampere rating of 30 A, an interrupting rating of 10kAIC, and a voltage rating of 120/240V.

Specifications

Application

Model 3 Ground Fault Circuit Interrupter (GFCI)

Brand Name

Q-Line (Plug-In)

Frame

Q-Line

Interrupt Rating

10kA@120 Vac

Load Rating

HACR

Number Of Poles

1

Special Features

Ground fault circuit interrupter (GFCI) breakers provide protection of receptacles located in the outdoors, in bathrooms, garages and spa areas. This applies to not only to new construction, but also to existing homes. When an electrical outlet is replaced in a location that requires ground-fault protection, the new outlet must be GFCI approved according to the NEC. All Q Line circuit breakers are one inch wide per pole, compact devices that feature: Quick-make / Quick-break mechanisms, common trip bars, and easy-to-spot trip indications to ensure safety and reliability as well as meets 2020 NEC standards. The THQL1130GFT breaker features ground fault interrupting technology, 1 pole, an ampere rating of 30 A, an interrupting rating of 10kAIC, and a voltage rating of 120/240V.

Standard

E51075

Sub Brand

Q-Line Model 3

Trip Range

Non-Interchangeable

Trip Type

LIG

Voltage Rating

120/240 V

Amperage Rating

30 A

Specifications

Specifications

Amperage Rating30 A
ApplicationModel 3 Ground Fault Circuit Interrupter (GFCI)
Brand NameQ-Line (Plug-In)
FrameQ-Line
Interrupt Rating10kA@120 Vac
Load RatingHACR
Number Of Poles1
Special FeaturesGround fault circuit interrupter (GFCI) breakers provide protection of receptacles located in the outdoors, in bathrooms, garages and spa areas. This applies to not only to new construction, but also to existing homes. When an electrical outlet is replaced in a location that requires ground-fault protection, the new outlet must be GFCI approved according to the NEC. All Q Line circuit breakers are one inch wide per pole, compact devices that feature: Quick-make / Quick-break mechanisms, common trip bars, and easy-to-spot trip indications to ensure safety and reliability as well as meets 2020 NEC standards. The THQL1130GFT breaker features ground fault interrupting technology, 1 pole, an ampere rating of 30 A, an interrupting rating of 10kAIC, and a voltage rating of 120/240V.
StandardE51075
Sub BrandQ-Line Model 3
Trip RangeNon-Interchangeable
Trip TypeLIG
Voltage Rating120/240 V