Skip to main content
IIDM Logo
286-792

Description

Optocoupler module; Red status indicator; gray

Technical data
Control circuit

Nominal input voltage UN

DC 24 V

Input voltage range (high level)

DC 7.5 … 30 V

Nominal input current at UN

15 mA

Load circuit

Circuit type

2-way

2-wire connection

Limiting continuous current

0.25 A

Nominal output voltage

DC 24 V

Output voltage range

DC 20 … 30 V

Voltage drop at output (max.)

≤ DC 2.5 V

Leakage current at rated voltage

≤ 3 µA

Turn-on time

≤ 60 µs

Turn-off time

≤ 120 µs

Switching frequency

≤ 1.5 kHz

Safety and protection

Pollution degree

2

Dielectric strength (control/load circuit) (AC, 1 min)

2.5 kVrms

Protection type

IP20

Physical data

Width

20 mm / 0.787 inch

Height from upper-edge of DIN-rail

82.5 mm / 3.25 inch

Depth

52 mm / 2.047 inch

Mechanical data

Mounting type

Pluggable module for receptacle terminal blocks

Material data

Color

gray

Fire load

0.394

Weight

23.4

Environmental requirements

Ambient temperature (operation at UN)

-25 … 40 °C

Surrounding air temperature (storage)

-25 … +40 °C

Processing temperature

-25 … +50 °C

Relative humidity

5 … 95 % (no condensation permissible)

Operating altitude (max.)

2000

Standards and specifications

Standards/specifications

EN 60664-1

Specifications

Environmental requirements

Ambient Temperature (Operation At UN)-25 … 40 °C
Operating Altitude (Max.)2000
Processing Temperature-25 … +50 °C
Relative Humidity5 … 95 % (no condensation permissible)
Surrounding Air Temperature (Storage)-25 … +40 °C

Material data

Colorgray
Fire Load0.394
Weight23.4

Mechanical data

Mounting TypePluggable module for receptacle terminal blocks

Physical data

Depth52 mm / 2.047 inch mm
Height52 mm / 2.047 inch mm
Height From Upper-Edge Of DIN-Rail82.5 mm / 3.25 inch
Width20 mm / 0.787 inch mm

Standards and specifications

Standards/SpecificationsEN 60664-1

Technical data › Control circuit

Input Voltage Range (High Level)DC 7.5 … 30 V
Nominal Input Current At UN15 mA
Nominal Input Voltage UNDC 24 V

Technical data › Load circuit

Circuit Type2-way | 2-wire connection
Leakage Current At Rated Voltage≤ 3 µA
Limiting Continuous Current0.25 A
Nominal Output VoltageDC 24 V
Output Voltage RangeDC 20 … 30 V
Switching Frequency≤ 1.5 kHz
Turn-Off Time≤ 120 µs
Turn-On Time≤ 60 µs
Voltage Drop At Output (Max.)≤ DC 2.5 V

Technical data › Safety and protection

Dielectric Strength (Control/Load Circuit) (AC, 1 Min)2.5 kVrms
Pollution Degree2
Protection TypeIP20