Description

Productfeatures
  • Memory card
  • conversion of the field bus protocols by software
  • integrated SD-Bus-Gateway
  • Safe drive monitoring according to EN 61800-5-2 (SDM – Safe Drive Monitoring) for up to 2 axes
  • Modular expansion with up to 64 inputs / outputs
  • 4 safe 2 A pp-switching semiconductor outputs, switchable to 2 safe p- / n-switching semiconductor outputs
  • 14 safe inputs on the base module
  • 2 Signalling outputs
  • 2 safety relay contacts
Data
Ordering data

Product type description

PSC1-C-10-SDM2-FB2

Article number (order number)

103008450

EAN (European Article Number)

4030661455112

eCl@ss number, version 9.0

27-24-22-07

eCl@ss number, version 11.0

27-24-22-07

eCl@ss number, version 12.0

27-24-22-07

ETIM number, version 7.0

EC000236

ETIM number, version 6.0

EC000236

Approvals - Standards

Certificates

TÜV

cULus

EAC

General data

Terminal (mechanical)

Removable screw terminals

Gross weight

805.2 g

General data - Features

SD Card Slot

Yes

Master-Slave-Kommunikation

Yes

Master-Master-Kommunikation

Yes

Integrated SD gateway

Yes

Number of pulse outputs (test pulse output)

2

Number of relay outputs (1-channel)

2

Number of digital fail-safe inputs

14

Number of fail-safe digital outputs

4

Number of signalling outputs

2

Anzahl der Erweiterungsbaugruppen, maximal

2

Mechanical data

Mounting

can be clipped into standard rail

Mechanical data - Connection technique

Cable section, minimum

0.2 mm²

Cable section, maximum

2.5 mm²

Wire cross-section, minimum

24 AWG

Wire cross-section, maximum

12 AWG

Mechanical data - Dimensions

Width

90 mm

Height

100 mm

Depth

115 mm

Ambient conditions

Degree of protection

IP20

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+50 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Relative humidity, minimum

5 %

Relative humidity, maximum

85 %

Note (Relative humidity)

non-condensing

Permissible installation altitude above sea level, maximum

2,000 m

Ambient conditions - Insulation values

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

2

Electrical data

Operating voltage, minimum

20.4 VDC

Operating voltage, maximum

28.8 VDC

Electrical data - Universal communication interface

Designation, Communication interface

DSUB

Electrical data - Communication protocols

Field bus

CANopen

PROFIBUS

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

2,000 mA

Design of switching elements

short-circuit proof, p-type (Q2 und Q3)

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

2 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

2 A

Electrical data - Electromagnetic compatibility (EMC)

Electromagnetic compatibility

DIN EN 62061

DIN EN 61800-3

Interfering radiation

DIN EN 61000-6-4

EMC rating

DIN EN 61000-6-7

DIN EN 61326-3

DIN EN 61000-6-2

Electrical data - Spindle monitoring

Number of axis monitoring, max.

2

Drive monitoring, encoder typ

SSI

TTL

SINCOS

Proximity switch

Specifications

Data › Ambient conditions

Ambient Temperature, Maximum+50 °C
Ambient Temperature, Minimum+0 °C
Degree Of ProtectionIP20
Note (Relative Humidity)non-condensing
Permissible Installation Altitude Above Sea Level, Maximum2,000 m
Relative Humidity, Maximum85 %
Relative Humidity, Minimum5 %
Storage And Transport Temperature, Maximum+70 °C
Storage And Transport Temperature, Minimum-25 °C

Data › Ambient conditions - Insulation values

Degree Of Pollution To IEC/EN 60664-12
Overvoltage CategoryIII

Data › Approvals - Standards

CertificatesTÜV | cULus | EAC

Data › Electrical data

Operating Voltage, Maximum28.8 VDC
Operating Voltage, Minimum20.4 VDC

Data › Electrical data - Communication protocols

Field BusCANopen | PROFIBUS

Data › Electrical data - Electromagnetic compatibility (EMC)

Electromagnetic CompatibilityDIN EN 62061 | DIN EN 61800-3
EMC RatingDIN EN 61000-6-7 | DIN EN 61326-3 | DIN EN 61000-6-2
Interfering RadiationDIN EN 61000-6-4

Data › Electrical data - Safe relay outputs

Current, Utilisation Category AC-152 A
Current, Utilisation Category DC-132 A
Voltage, Utilisation Category AC-15230 VAC
Voltage, Utilisation Category DC-1324 VDC

Data › Electrical data - Safety digital outputs

Design Of Switching Elementsshort-circuit proof, p-type (Q2 und Q3)
Rated Operating Current (Safety Outputs)2,000 mA

Data › Electrical data - Spindle monitoring

Drive Monitoring, Encoder TypSSI | TTL | SINCOS | Proximity switch
Number Of Axis Monitoring, Max.2

Data › Electrical data - Universal communication interface

Designation, Communication InterfaceDSUB

Data › General data

Gross Weight805.2 g
Terminal (Mechanical)Removable screw terminals

Data › General data - Features

Anzahl Der Erweiterungsbaugruppen, Maximal2
Integrated SD GatewayYes
Master-Master-KommunikationYes
Master-Slave-KommunikationYes
Number Of Digital Fail-Safe Inputs14
Number Of Fail-Safe Digital Outputs4
Number Of Pulse Outputs (Test Pulse Output)2
Number Of Relay Outputs (1-Channel)2
Number Of Signalling Outputs2
SD Card SlotYes

Data › Mechanical data

Mountingcan be clipped into standard rail

Data › Mechanical data - Connection technique

Cable Section, Maximum2.5 mm²
Cable Section, Minimum0.2 mm²
Wire Cross-Section, Maximum12 AWG
Wire Cross-Section, Minimum24 AWG

Data › Mechanical data - Dimensions

Depth115 mm mm
Height100 mm mm
Width90 mm mm

Data › Ordering data

Article Number (Order Number)103008450
EAN (European Article Number)4030661455112
ECl@Ss Number, Version 11.027-24-22-07
ECl@Ss Number, Version 12.027-24-22-07
ECl@Ss Number, Version 9.027-24-22-07
ETIM Number, Version 6.0EC000236
ETIM Number, Version 7.0EC000236
Product Type DescriptionPSC1-C-10-SDM2-FB2

More from Schmersal