Skip to main content
IIDM Logo
101215377

Description

Productfeatures
  • Simple and flexible parameter setting
  • No programming skills required
  • 18 safe inputs for the redundant inquiry of all common safety sensors
  • 4 safety semi-conductor outputs
  • 2 safety relay outputs
  • 4 optional signalling outputs
  • Replaces up to 8 safety-monitoring modules up to PL e / SIL 3
  • Error and status messages in plain text
  • Multilingual menu navigation via colour display
Data
Ordering data

Product type description

PROTECT-SELECT-CC

Article number (order number)

101215377

EAN (European Article Number)

4030661445403

eCl@ss number, version 9.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 12.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

TÜV

cULus

CCC

EAC

General data

Standards

EN 60204-1

EN 60947-5-1

EN 62061

EN ISO 13849-1

IEC 61508

Climatic stress

EN 60068-2-1

EN 60068-2-2

EN 61496

Terminal (mechanical)

Removable cage terminals

Enclosure material

Polyamide / V0

Material of the contacts, electrical

Tin

Gross weight

300 g

General data - Features

Short circuit detection

Yes

Wire breakage detection

Yes

Cross-circuit detection

Yes

Removable Terminals

Yes

Start input

Yes

Feedback circuit

Yes

Automatic reset function

Yes

Reset edge detection

Yes

Start-up test

Yes

Earth connection detection

Yes

Integral system diagnostics, status

Yes

Integrated Display, Supply Voltage

Yes

Number of pulse outputs (test pulse output)

3

Number of relay outputs (1-channel)

2

Number of fail-safe analogue inputs

2

Number of digital fail-safe inputs

14

Number of digital fail-safe in-/outputs

4

Number of fail-safe digital outputs

4

Number of signalling outputs

4

Mechanical data

Mechanical life, minimum

10,000,000 Operations

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Type of connection

rigid or flexible

Terminal designations

IEC 61131-2

IEC/EN 60947-1

Cable section, minimum

0.25 mm²

Cable section, maximum

2.5 mm²

Mechanical data - Dimensions

Width

52.5 mm

Height

100 mm

Depth

118 mm

Ambient conditions

Degree of protection

IP20

Degree of protection of the mounting space

IP54

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+75 °C

Relative humidity, minimum

15 %

Relative humidity, maximum

90 %

Note (Relative humidity)

non-condensing

Resistance to vibration to EN 60068-2-6

10 … 57 Hz, amplitude 0.75 mm

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Overvoltage category

III

Degree of pollution to VDE 0100

2

Electrical data

Voltage type

DC (direct current)

Operating voltage

24 V

Operating voltage, minimum

21.6 VDC

Operating voltage, maximum

26.4 VDC

Current consumption at 24V, maximum

500 mA

No-load supply current, maximum I

500 mA

Required rated short-circuit current to EN 60947-5-1

1,000 A

Switching frequency, maximum

0.1 Hz

Specifications

Data › Ambient conditions

Ambient Temperature, Maximum+55 °C
Ambient Temperature, Minimum-25 °C
Degree Of ProtectionIP20
Degree Of Protection Of The Mounting SpaceIP54
Note (Relative Humidity)non-condensing
Relative Humidity, Maximum90 %
Relative Humidity, Minimum15 %
Resistance To Vibration To EN 60068-2-610 … 57 Hz, amplitude 0.75 mm
Restistance To Shock30 g / 11 ms
Storage And Transport Temperature, Maximum+75 °C
Storage And Transport Temperature, Minimum-25 °C

Data › Ambient conditions - Insulation values

Degree Of Pollution To VDE 01002
Overvoltage CategoryIII

Data › Approvals - Standards

CertificatesTÜV | cULus | CCC | EAC

Data › Electrical data

Current Consumption At 24V, Maximum500 mA
No-Load Supply Current, Maximum I500 mA
Operating Voltage24 V
Operating Voltage, Maximum26.4 VDC
Operating Voltage, Minimum21.6 VDC
Required Rated Short-Circuit Current To EN 60947-5-11,000 A
Switching Frequency, Maximum0.1 Hz
Voltage TypeDC (direct current)

Data › General data

Climatic StressEN 60068-2-1 | EN 60068-2-2 | EN 61496
Enclosure MaterialPolyamide / V0
Gross Weight300 g
Material Of The Contacts, ElectricalTin
StandardsEN 60204-1 | EN 60947-5-1 | EN 62061 | EN ISO 13849-1 | IEC 61508
Terminal (Mechanical)Removable cage terminals

Data › General data - Features

Automatic Reset FunctionYes
Cross-Circuit DetectionYes
Earth Connection DetectionYes
Feedback CircuitYes
Integral System Diagnostics, StatusYes
Integrated Display, Supply VoltageYes
Number Of Digital Fail-Safe In-/Outputs4
Number Of Digital Fail-Safe Inputs14
Number Of Fail-Safe Analogue Inputs2
Number Of Fail-Safe Digital Outputs4
Number Of Pulse Outputs (Test Pulse Output)3
Number Of Relay Outputs (1-Channel)2
Number Of Signalling Outputs4
Removable TerminalsYes
Reset Edge DetectionYes
Short Circuit DetectionYes
Start InputYes
Start-Up TestYes
Wire Breakage DetectionYes

Data › Mechanical data

Mechanical Life, Minimum10,000,000 Operations
MountingSnaps onto standard DIN rail to EN 60715

Data › Mechanical data - Connection technique

Cable Section, Maximum2.5 mm²
Cable Section, Minimum0.25 mm²
Terminal DesignationsIEC 61131-2 | IEC/EN 60947-1
Type Of Connectionrigid or flexible

Data › Mechanical data - Dimensions

Depth118 mm mm
Height100 mm mm
Width52.5 mm mm

Data › Ordering data

Article Number (Order Number)101215377
EAN (European Article Number)4030661445403
ECl@Ss Number, Version 11.027-37-18-19
ECl@Ss Number, Version 12.027-37-18-19
ECl@Ss Number, Version 9.027-37-18-19
ETIM Number, Version 6.0EC001449
ETIM Number, Version 7.0EC001449
Product Type DescriptionPROTECT-SELECT-CC