Skip to main content
IIDM Logo
101212555

Description

Productfeatures
  • Suitable for the signal processing of outputs with contact sensors
  • 2 safety contacts, STOP 0
  • 1 Signalling output
Data
Ordering data

Product type description

SRB201LC

Article number (order number)

101212555

EAN (European Article Number)

4030661448916

eCl@ss number, version 9.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 12.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Available until

31.12.2022

Approvals - Standards

Certificates

TÜV

EAC

General data

Standards

EN 60947-5-1

EN ISO 13849-1

IEC 61508

IEC/EN 60204-1

Climatic stress

EN 60068-2-78

Enclosure material

Glass-fibre reinforced thermoplastic, ventilated

Material of the contacts, electrical

AgSn0. self-cleaning, positive drive

Gross weight

200 g

General data - Features

Stop-Category

0

1

Wire breakage detection

Yes

Feedback circuit

Yes

Automatic reset function

Yes

Earth connection detection

Yes

Integral system diagnostics, status

Yes

Number of LEDs

3

Number of openers

2

Number of undelayed semi-conductor outputs with signaling function

1

Number of safety contacts

2

Number of signalling outputs

1

Mechanical data

Mechanical life, minimum

10,000,000 Operations

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Type of connection

Screw terminals M20 x 1.5

rigid or flexible

Terminal designations

IEC/EN 60947-1

Cable section, minimum

0.25 mm²

Cable section, maximum

2.5 mm²

Tightening torque of Clips

0.6 Nm

Mechanical data - Dimensions

Width

22.5 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-40 °C

Storage and transport temperature, maximum

+85 °C

Resistance to vibration to EN 60068-2-6

10...55 Hz, Amplitude 0.35 mm, ± 15 %

Restistance to shock

10 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage U

4 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

2

Electrical data

Frequency range

50 Hz

60 Hz

Rated operating voltage

24 VAC -15% / +10%

24 VDC -15% / +20%, residual ripple max. 10 %

Rated AC voltage for controls, 50 Hz, minimum

20.4 VAC

Rated control voltage at AC 50 Hz, maximum

26.4 VAC

Rated AC voltage for controls, 60 Hz, minimum

20.4 VAC

Rated control voltage at AC 60 Hz, maximum

26.4 VAC

Rated AC voltage for controls at DC minimum

20.4 VDC

Rated control voltage at DC, maximum

28.8 VDC

Electrical power consumption

2 W

Electrical power consumption

5.2 VA

Contact resistance, maximum

0.1 Ω

Note (Contact resistance)

in new state

Drop-out delay in case of power failure, typically

80 ms

Drop-out delay in case of emergency, typically

20 ms

Pull-in delay at automatic start, maximum, typically

100 ms

Pull-in delay at RESET, typically

20 ms

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

6 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

6 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

8 A

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Status indication

Indicated operating states

Position relay K2

Position relay K1

Internal operating voltage U

Other data

Note (applications)

Guard system

Emergency-Stop button

Pull-wire emergency stop switches

Safety light curtain

Specifications

Data › Ambient conditions

Ambient Temperature, Maximum+60 °C
Ambient Temperature, Minimum-25 °C
Degree Of Protection Of Clips Or TerminalsIP20
Degree Of Protection Of The EnclosureIP40
Degree Of Protection Of The Mounting SpaceIP54
Resistance To Vibration To EN 60068-2-610...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance To Shock10 g / 11 ms
Storage And Transport Temperature, Maximum+85 °C
Storage And Transport Temperature, Minimum-40 °C

Data › Ambient conditions - Insulation values

Degree Of Pollution To IEC/EN 60664-12
Overvoltage CategoryIII
Rated Impulse Withstand Voltage U4 kV

Data › Approvals - Standards

CertificatesTÜV | EAC

Data › Electrical data

Contact Resistance, Maximum0.1 Ω
Drop-Out Delay In Case Of Emergency, Typically20 ms
Drop-Out Delay In Case Of Power Failure, Typically80 ms
Electrical Power Consumption2 W | 5.2 VA
Frequency Range50 Hz | 60 Hz
Note (Contact Resistance)in new state
Pull-In Delay At Automatic Start, Maximum, Typically100 ms
Pull-In Delay At RESET, Typically20 ms
Rated AC Voltage For Controls, 50 Hz, Minimum20.4 VAC
Rated AC Voltage For Controls, 60 Hz, Minimum20.4 VAC
Rated AC Voltage For Controls At DC Minimum20.4 VDC
Rated Control Voltage At AC 50 Hz, Maximum26.4 VAC
Rated Control Voltage At AC 60 Hz, Maximum26.4 VAC
Rated Control Voltage At DC, Maximum28.8 VDC
Rated Operating Voltage24 VAC -15% / +10% | 24 VDC -15% / +20%, residual ripple max. 10 %

Data › Electrical data - Digital inputs

Conduction Resistance, Maximum40 Ω

Data › Electrical data - Electromagnetic compatibility (EMC)

EMC RatingEMC-Directive

Data › Electrical data - Safe relay outputs

Current, Utilisation Category AC-156 A
Current, Utilisation Category DC-136 A
Switching Capacity, Maximum250 VAC | 8 A | 24 VDC | 2 A
Switching Capacity, Minimum10 VDC | 10 mA
Voltage, Utilisation Category AC-15230 VAC
Voltage, Utilisation Category DC-1324 VDC

Data › General data

Climatic StressEN 60068-2-78
Enclosure MaterialGlass-fibre reinforced thermoplastic, ventilated
Gross Weight200 g
Material Of The Contacts, ElectricalAgSn0. self-cleaning, positive drive
StandardsEN 60947-5-1 | EN ISO 13849-1 | IEC 61508 | IEC/EN 60204-1

Data › General data - Features

Automatic Reset FunctionYes
Earth Connection DetectionYes
Feedback CircuitYes
Integral System Diagnostics, StatusYes
Number Of LEDs3
Number Of Openers2
Number Of Safety Contacts2
Number Of Signalling Outputs1
Number Of Undelayed Semi-Conductor Outputs With Signaling Function1
Stop-Category0 | 1
Wire Breakage DetectionYes

Data › Mechanical data

Mechanical Life, Minimum10,000,000 Operations
MountingSnaps onto standard DIN rail to EN 60715

Data › Mechanical data - Connection technique

Cable Section, Maximum2.5 mm²
Cable Section, Minimum0.25 mm²
Terminal DesignationsIEC/EN 60947-1
Tightening Torque Of Clips0.6 Nm
Type Of ConnectionScrew terminals M20 x 1.5 | rigid or flexible

Data › Mechanical data - Dimensions

Depth121 mm mm
Height100 mm mm
Width22.5 mm mm

Data › Ordering data

Article Number (Order Number)101212555
Available Until31.12.2022
EAN (European Article Number)4030661448916
ECl@Ss Number, Version 11.027-37-18-19
ECl@Ss Number, Version 12.027-37-18-19
ECl@Ss Number, Version 9.027-37-18-19
ETIM Number, Version 6.0EC001449
ETIM Number, Version 7.0EC001449
Product Type DescriptionSRB201LC

Data › Other data

Note (Applications)Guard system | Emergency-Stop button | Pull-wire emergency stop switches | Safety light curtain

Data › Status indication

Indicated Operating StatesPosition relay K2 | Position relay K1 | Internal operating voltage U

Similar products